XPRO 900 Series Selection Guide

The following tables can be used to help select the correct XPRO valve controller for your requirement.

For further information, or to purchase a product, please contact us and we will be pleased to assist.


WATTAGE
VOLTAGE
COIL OHMS
STANDARD
ADJUSTABLE DITHER/PWM
ADJUSTABLE RAMP UP, DOWN & IMIN
ADJUSTABLE RAMP UP, DOWN, IMIN & DITHER/PWM
19W
30W
12V
12V
7.5
4.8
902
932
902d
932d
902ri
932ri
902rid
932rid
19W
30W
24V
24V
30.3
19.2
904
934
904d
934d
904ri
934ri
904rid
934rid

Parameters
Min
Nominal
Max
12V supply range
10v
12v
15v
24V supply range
18v
24v
30v
I max adjustment range
0%
-
100%
I min adjustment range
0%
-
100%
Fixed dither frequency
-
110Hz
+/-5%
Adjustable dither range
95Hz
-
230Hz
Ramp up adjustment range
200ms
-
8 sec
Ramp down adjustment range
200ms
-
8 sec
Standard operating response
-
100ms
+/-5%

Command input resistance 10,000 Ohms
Command input voltage 10v


Peter J Hill Associates Ltd.
Unit 2, The Modern Moulds Business Centre
Commerce Way, Lancing, West Sussex
BN15 8TA
Tel: 01903 851032
Email: info@peterjhillassocs.co.uk


ENGINEERING CONSULTANCY | XPRO VALVE CONTROLLERS
CONTACT US | HOME